Wuxi Deep Sea Heat Transfer Technology Co., Ltd.-What is the function of the balance pipe, fan and side fan of the closed cooling tower?
Release time:
2022-06-17
Since the closed cooling tower of Wuxi Deep Sea Heat Transfer Technology Co., Ltd. uses soft water as the cooling medium, the material is cheap and will not block the pipeline, so it is widely used in industry. Its balance tube, fan and side fan play a big role in it, let's take a look with the fluid cooling tower manufacturer.
1. The role of the balance tube
When several closed cooling towers are installed in parallel, the connecting pipe between the collecting pans is also called the cooling tower balance pipe. In addition, the equipment itself is mainly used to balance the water level between the water collecting trays of each cooling tower, so that the water flow can be maintained evenly, and the pressure between the towers is relatively close, so that there will be no excessive water in one and another in the water. too small.
2. The role of the fan
When the fan in the closed cooling tower is actually used, the low-temperature air can be introduced into the cooling tower, and then the hot air in the cooling tower can be drawn out of the tower body. With the operation of the fan, the heat exchange between the low temperature air and the hot water can be carried out on the packing, which has a cooling effect.
3. The role of the side fan
At this time, we will analyze the structure of the air inlet and side air outlet of the closed cooling tower from the aspect of appearance. This structure greatly reduces the height of the cooling tower, making the height of the closed cooling tower less than 3 meters, suitable for It is installed on the technical equipment layer or middle layer of general buildings and high-rise buildings, which solves the problem of inconvenient installation at the top of the cooling tower.
The structure of the air inlet and side air outlet in the closed cooling tower also greatly reduces the backflow of warm air in the cooling tower installed in the above position, and improves the cooling efficiency of the cooling tower. Since it is installed in the middle layer, the working head of the air-conditioning circulating water system is reduced, thereby saving the construction cost of the air-conditioning system and greatly reducing the operating cost of the system.
The structure of the air inlet and side air outlet in the closed cooling tower also greatly reduces the backflow of warm air in the cooling tower installed in the above-mentioned position, and improves the cooling efficiency of the cooling tower.