SHBN Counterflow Fluid Cooling Tower
The counter-flow cooling method is adopted, with very few blind spots for heat dissipation and high heat exchange efficiency;
Category:
Product Description
Product Features
The counter-flow cooling method is adopted, with fewer blind spots for heat dissipation and high heat exchange efficiency;
Professional water collector to control the drift rate≤0.001%;
High air duct design ensures that the air volume of the equipment can meet the cooling requirements;
Compared with other forms of cooling towers, the floor space is reduced to meet user space requirements;
The box adopts closed circulation to prevent debris from entering the tower and causing spray blockage;
The cooler adopts an anti-freezing and energy-saving design to ensure that the circulating water is drained to avoid freezing damage when the temperature is lower in the northern region;
Double-loop cycle can be designed according to user equipment requirements, even if one loop fails, the other loop can run normally;
The design of the unit is beautiful and generous, with automatic digital display, and the operation and maintenance are simple and easy.
Product Map

Parameter list
|
Model
|
Cooling amount
|
fan
|
Spray Pump
|
Weight (split)
|
Dimensions (length, width and height) mm
|
Inlet and outlet diameter
|
Water replenishment caliber
|
Sewage diameter
|
|||||
|
Type
|
Kcal
|
Kw
|
Power Kw
|
Air volume m3/h
|
Power Kw
|
Flow T/h
|
Head m
|
Transport Kg
|
Run Kg
|
Split
|
DN
|
DN
|
DN
|
|
SHBN-10
|
50000
|
58
|
1.1×1
|
16000
|
0.75
|
20
|
7
|
500
|
800
|
1550×1150×2500
|
50
|
20
|
25
|
|
SHBN-15
|
75000
|
87
|
2.2×1
|
28000
|
680
|
1050
|
2000×1150×2600
|
50
|
20
|
25
|
|||
|
SHBN-20
|
100000
|
116
|
1.1×2
|
32000
|
750
|
120C
|
2300×1150×2600
|
65
|
20
|
25
|
|||
|
SHBN-25
|
125000
|
145
|
1.1×2
|
32000
|
11
|
45
|
5
|
850
|
1390
|
2850×1150×2800
|
65
|
25
|
32
|
|
SHBN-30
|
150000
|
174
|
1.5×2
|
40000
|
1200
|
2700
|
2850×1150×2800
|
80
|
25
|
32
|
|||
|
SHBN-40
|
200000
|
233
|
2.2×2
|
56000
|
1.5
|
65
|
6
|
1550
|
3200
|
2850×1600×2960
|
80
|
25
|
32
|
|
SHBN-50
|
250000
|
291
|
2.2×2
|
56000
|
1680
|
3450
|
2850×1600×2960
|
80
|
25
|
32
|
|||
|
SHBN-60
|
300000
|
348
|
2.2×2
|
60000
|
2.2
|
100
|
5
|
1850
|
3700
|
3650×1600×3230
|
100
|
25
|
32
|
|
SHBN-70
|
350000
|
407
|
3×2
|
80000
|
2000
|
4000
|
3650×1600×3350
|
100
|
25
|
32
|
|||
|
SHBN-80
|
400000
|
465
|
3×2
|
86000
|
2350
|
4560
|
3650×1900×3570
|
125
|
32
|
40
|
|||
|
SHBN-100
|
500000
|
581
|
3×2
|
100000
|
3
|
150
|
5
|
2790
|
5380
|
4300×1900×3600 |
100×2
|
32
|
40
|
|
SHBN-125
|
625000
|
727
|
4×2
|
120000
|
3200
|
6660
|
4300×2200×3720
|
100×2
|
32
|
40
|
|||
|
SHBN-150
|
750000
|
872
|
5.5×2
|
160000
|
3800
|
8000
|
5000×2200×4100
|
125×2
|
40
|
50
|
|||
|
SHBN-180
|
900000
|
1046
|
7.5×2
|
192000
|
5.5
|
230
|
6
|
4250
|
9300
|
5300×2200×4100
|
125×2
|
40
|
50
|
|
SHBN-200
|
1000000
|
1163
|
7.5×2
|
230000
|
5000
|
11200
|
5300×2700×4420
|
150×2
|
40
|
50
|
|||
|
SHBN-230
|
1150000
|
1337
|
7.5×2
|
260000
|
5220
|
12500
|
5300×2900×4620
|
150×2
|
40
|
50
|
|||
|
SHBN-250
|
1250000
|
1453
|
7.5×2
|
260000
|
7.5
|
280
|
6
|
5800
|
13000
|
6300×2900×4620
|
15O×2
|
40
|
50
|
|
SHBN-280
|
1400000
|
1628
|
11×2
|
280000
|
6290
|
13900
|
6300×3000×4910
|
150×2
|
50
|
65
|
|||
|
SHBN-300
|
1500000
|
1744
|
11×2
|
280000
|
3×2
|
300
|
5
|
6800
|
14900
|
7000×3000×5160
|
200×2
|
50
|
65
|
|
SHBN-350
|
1750000
|
2034
|
15×2
|
360000
|
7500
|
15500
|
7000×3200×5260
|
200×2
|
50
|
65
|
|||
|
SHBN-400
|
2000000
|
2326
|
15×2
|
400000
|
5.5×2
|
460
|
6
|
8260
|
16360
|
7800×3200×5560
|
200×2
|
50
|
65
|
|
SHBN-450
|
2250000
|
2616
|
18.5×2
|
490000
|
9210
|
18200
|
8200×3200×5560
|
200×2
|
50
|
65
|
|||
|
SHBN-500
|
2500000
|
2907
|
18.5×2
|
540000
|
7.5×
|
560
|
6
|
9950
|
19950
|
9100×3400×5560
|
200×2
|
50
|
65
|
Note: The parameter changes caused by equipment modification will not be notified beforehand. The specific parameters are mainly based on our plan.
SHBN Counterflow Fluid Cooling Tower
The counter-flow cooling method is adopted, with very few blind spots for heat dissipation and high heat exchange efficiency;
Category:
Product Description
Product Features
The counter-flow cooling method is adopted, with fewer blind spots for heat dissipation and high heat exchange efficiency;
Professional water collector to control the drift rate≤0.001%;
High air duct design ensures that the air volume of the equipment can meet the cooling requirements;
Compared with other forms of cooling towers, the floor space is reduced to meet user space requirements;
The box adopts closed circulation to prevent debris from entering the tower and causing spray blockage;
The cooler adopts an anti-freezing and energy-saving design to ensure that the circulating water is drained to avoid freezing damage when the temperature is lower in the northern region;
Double-loop cycle can be designed according to user equipment requirements, even if one loop fails, the other loop can run normally;
The design of the unit is beautiful and generous, with automatic digital display, and the operation and maintenance are simple and easy.
Product Map

Parameter list
|
Model
|
Cooling amount
|
fan
|
Spray Pump
|
Weight (split)
|
Dimensions (length, width and height) mm
|
Inlet and outlet diameter
|
Water replenishment caliber
|
Sewage diameter
|
|||||
|
Type
|
Kcal
|
Kw
|
Power Kw
|
Air volume m3/h
|
Power Kw
|
Flow T/h
|
Head m
|
Transport Kg
|
Run Kg
|
Split
|
DN
|
DN
|
DN
|
|
SHBN-10
|
50000
|
58
|
1.1×1
|
16000
|
0.75
|
20
|
7
|
500
|
800
|
1550×1150×2500
|
50
|
20
|
25
|
|
SHBN-15
|
75000
|
87
|
2.2×1
|
28000
|
680
|
1050
|
2000×1150×2600
|
50
|
20
|
25
|
|||
|
SHBN-20
|
100000
|
116
|
1.1×2
|
32000
|
750
|
120C
|
2300×1150×2600
|
65
|
20
|
25
|
|||
|
SHBN-25
|
125000
|
145
|
1.1×2
|
32000
|
11
|
45
|
5
|
850
|
1390
|
2850×1150×2800
|
65
|
25
|
32
|
|
SHBN-30
|
150000
|
174
|
1.5×2
|
40000
|
1200
|
2700
|
2850×1150×2800
|
80
|
25
|
32
|
|||
|
SHBN-40
|
200000
|
233
|
2.2×2
|
56000
|
1.5
|
65
|
6
|
1550
|
3200
|
2850×1600×2960
|
80
|
25
|
32
|
|
SHBN-50
|
250000
|
291
|
2.2×2
|
56000
|
1680
|
3450
|
2850×1600×2960
|
80
|
25
|
32
|
|||
|
SHBN-60
|
300000
|
348
|
2.2×2
|
60000
|
2.2
|
100
|
5
|
1850
|
3700
|
3650×1600×3230
|
100
|
25
|
32
|
|
SHBN-70
|
350000
|
407
|
3×2
|
80000
|
2000
|
4000
|
3650×1600×3350
|
100
|
25
|
32
|
|||
|
SHBN-80
|
400000
|
465
|
3×2
|
86000
|
2350
|
4560
|
3650×1900×3570
|
125
|
32
|
40
|
|||
|
SHBN-100
|
500000
|
581
|
3×2
|
100000
|
3
|
150
|
5
|
2790
|
5380
|
4300×1900×3600 |
100×2
|
32
|
40
|
|
SHBN-125
|
625000
|
727
|
4×2
|
120000
|
3200
|
6660
|
4300×2200×3720
|
100×2
|
32
|
40
|
|||
|
SHBN-150
|
750000
|
872
|
5.5×2
|
160000
|
3800
|
8000
|
5000×2200×4100
|
125×2
|
40
|
50
|
|||
|
SHBN-180
|
900000
|
1046
|
7.5×2
|
192000
|
5.5
|
230
|
6
|
4250
|
9300
|
5300×2200×4100
|
125×2
|
40
|
50
|
|
SHBN-200
|
1000000
|
1163
|
7.5×2
|
230000
|
5000
|
11200
|
5300×2700×4420
|
150×2
|
40
|
50
|
|||
|
SHBN-230
|
1150000
|
1337
|
7.5×2
|
260000
|
5220
|
12500
|
5300×2900×4620
|
150×2
|
40
|
50
|
|||
|
SHBN-250
|
1250000
|
1453
|
7.5×2
|
260000
|
7.5
|
280
|
6
|
5800
|
13000
|
6300×2900×4620
|
15O×2
|
40
|
50
|
|
SHBN-280
|
1400000
|
1628
|
11×2
|
280000
|
6290
|
13900
|
6300×3000×4910
|
150×2
|
50
|
65
|
|||
|
SHBN-300
|
1500000
|
1744
|
11×2
|
280000
|
3×2
|
300
|
5
|
6800
|
14900
|
7000×3000×5160
|
200×2
|
50
|
65
|
|
SHBN-350
|
1750000
|
2034
|
15×2
|
360000
|
7500
|
15500
|
7000×3200×5260
|
200×2
|
50
|
65
|
|||
|
SHBN-400
|
2000000
|
2326
|
15×2
|
400000
|
5.5×2
|
460
|
6
|
8260
|
16360
|
7800×3200×5560
|
200×2
|
50
|
65
|
|
SHBN-450
|
2250000
|
2616
|
18.5×2
|
490000
|
9210
|
18200
|
8200×3200×5560
|
200×2
|
50
|
65
|
|||
|
SHBN-500
|
2500000
|
2907
|
18.5×2
|
540000
|
7.5×
|
560
|
6
|
9950
|
19950
|
9100×3400×5560
|
200×2
|
50
|
65
|
Note: The parameter changes caused by equipment modification will not be notified beforehand. The specific parameters are mainly based on our plan.
Related Products
Inquiry
Scan and follow us
Copyright © 2022 Wuxi Deep Sea Heat Transfer Technology Co., Ltd. Website building:www.300.cn 苏ICP备2022022961号-1