图片名称
+

SHKN Square Counterflow Open Cooling Tower

Standard design conditions: dry bulb temperature 31.5°C, wet bulb temperature 28°C, atmospheric pressure 99400Pa, inlet water temperature 42°C, outlet water temperature 32°C;

Hotline:

Product Description

Product Features

Standard design conditions: dry bulb temperature 31.5°℃, wet bulb temperature 28°℃, atmospheric pressure 99400Pa, inlet water temperature 42°℃, outlet water temperature 32°℃;

The special packing for inclined trapezoidal wave square tower is selected, which has excellent thermal performance and small ventilation resistance, so that this type of cooling tower can achieve the design purpose of compact structure and small footprint;

The counter-flow square cooling tower adopts the airfoil-shaped hollow structure with large diameter, large area, low speed and low dynamic pressure FRP fan blades. The use of this type of cooling tower has the remarkable characteristics of energy saving and low noise;

The ultra-low noise cooling tower is equipped with noise reduction devices at the air inlet and outlet and the rain area, so that the cooling tower of the same level can effectively reduce the noise by 5dB(A);

It can be combined in parallel in various forms, which is more suitable for circulating cooling water systems with large amounts of water;

Using a fixed water distribution system and using ABS multi-layer flow low-pressure water spray nozzles, the water distribution is uniform, the service life is long, and the water distribution head is low, which is conducive to saving the water distribution power of the system;

Q-235 profiles and FRP profiles can be used for the frame of the counter-flow square cooling tower. Although the construction cycle is slightly longer and the one-time investment is high, it has excellent properties such as long service life and low maintenance cost, which can be easily viewed by users. Actual selection;

If the turbidity of circulating water is higher than 50ppm for a long time, or contains impurities such as oil pollution, PVC grid packing should be selected according to the water quality conditions. The turbidity of this packing can be extended to 450ppm for circulating water.

Parameter list

Model Dimension (mm) cooling water m3/h fanψmm Motor Kw Weight KG noise db
Long L width W high H Tower H1 Hair dryer H2 Net Weight Dry Run heavy Wet
SHKN-100 2460 2460 4280 3240 760 100 1800 4 1250 2320 61
SHKN-125 2460 2460 4430 3390 760 125 1800 4 1350 2497 62
SHKN-150 2760 2760 4720 3590 820 150 2100 5.5 1420 2627 63
SHKN-175 2760 2760 4720 3590 820 175 2100 5.5 1520 2812 63.5
SHKN-200 3370 3370 4930 3260 1000 200 2400 5.5 1770 3770 63.5
SHKN-250 3370 3370 5270 3560 1000 250 2400 7.5 1830 3890 64
SHKN-300 3980 3980 5160 3380 1000 300 3000 11 2960 6590 64
SHKN-350 3980 3980 5680 3900 1000 350 3000 11 3150 6790 64
SHKN-400 4895 4895 5330 3260 1200 400 3400 15 3450 7090 65
SHKN-450 4895 4895 5480 3410 1200 450 3400 15 4680 9760 65
SHKN-500 4895 4895 6070 3900 1200 500 3400 15 5420 12320 66
SHKN-600 5810 5810 5850 3650 1200 600 3600 18 5730 12960 66
SHKN-700 6725 6725 5650 3650 1000 700 4270 22 6890 16310 67

Note: The parameter changes caused by equipment modification will not be notified beforehand. The specific parameters are mainly based on our plan.

+

SHKN Square Counterflow Open Cooling Tower

Standard design conditions: dry bulb temperature 31.5°C, wet bulb temperature 28°C, atmospheric pressure 99400Pa, inlet water temperature 42°C, outlet water temperature 32°C;

Hotline:

Product Description

Product Features

Standard design conditions: dry bulb temperature 31.5°℃, wet bulb temperature 28°℃, atmospheric pressure 99400Pa, inlet water temperature 42°℃, outlet water temperature 32°℃;

The special packing for inclined trapezoidal wave square tower is selected, which has excellent thermal performance and small ventilation resistance, so that this type of cooling tower can achieve the design purpose of compact structure and small footprint;

The counter-flow square cooling tower adopts the airfoil-shaped hollow structure with large diameter, large area, low speed and low dynamic pressure FRP fan blades. The use of this type of cooling tower has the remarkable characteristics of energy saving and low noise;

The ultra-low noise cooling tower is equipped with noise reduction devices at the air inlet and outlet and the rain area, so that the cooling tower of the same level can effectively reduce the noise by 5dB(A);

It can be combined in parallel in various forms, which is more suitable for circulating cooling water systems with large amounts of water;

Using a fixed water distribution system and using ABS multi-layer flow low-pressure water spray nozzles, the water distribution is uniform, the service life is long, and the water distribution head is low, which is conducive to saving the water distribution power of the system;

Q-235 profiles and FRP profiles can be used for the frame of the counter-flow square cooling tower. Although the construction cycle is slightly longer and the one-time investment is high, it has excellent properties such as long service life and low maintenance cost, which can be easily viewed by users. Actual selection;

If the turbidity of circulating water is higher than 50ppm for a long time, or contains impurities such as oil pollution, PVC grid packing should be selected according to the water quality conditions. The turbidity of this packing can be extended to 450ppm for circulating water.

Parameter list

Model Dimension (mm) cooling water m3/h fanψmm Motor Kw Weight KG noise db
Long L width W high H Tower H1 Hair dryer H2 Net Weight Dry Run heavy Wet
SHKN-100 2460 2460 4280 3240 760 100 1800 4 1250 2320 61
SHKN-125 2460 2460 4430 3390 760 125 1800 4 1350 2497 62
SHKN-150 2760 2760 4720 3590 820 150 2100 5.5 1420 2627 63
SHKN-175 2760 2760 4720 3590 820 175 2100 5.5 1520 2812 63.5
SHKN-200 3370 3370 4930 3260 1000 200 2400 5.5 1770 3770 63.5
SHKN-250 3370 3370 5270 3560 1000 250 2400 7.5 1830 3890 64
SHKN-300 3980 3980 5160 3380 1000 300 3000 11 2960 6590 64
SHKN-350 3980 3980 5680 3900 1000 350 3000 11 3150 6790 64
SHKN-400 4895 4895 5330 3260 1200 400 3400 15 3450 7090 65
SHKN-450 4895 4895 5480 3410 1200 450 3400 15 4680 9760 65
SHKN-500 4895 4895 6070 3900 1200 500 3400 15 5420 12320 66
SHKN-600 5810 5810 5850 3650 1200 600 3600 18 5730 12960 66
SHKN-700 6725 6725 5650 3650 1000 700 4270 22 6890 16310 67

Note: The parameter changes caused by equipment modification will not be notified beforehand. The specific parameters are mainly based on our plan.

Inquiry